Specification
|
Item |
HBF1K |
HBF2K |
HBF3K |
Delivery period (Week) |
4 |
4 |
4 |
|
Type |
Outdoor |
Outdoor |
Outdoor |
|
Input DC |
Max DC power |
1.9KW |
2.8KW |
3.9KW |
Max. DC input voltage |
450V |
450V |
5000V |
|
MPP voltage range |
90-450V |
100-500V |
100V-500V |
|
Rated input voltage (V) |
360V |
360V |
360V |
|
Maximum input current |
10A |
15A |
15A |
|
Number of MPPT inputs |
1 |
1 |
1 |
|
Number of DC inputs |
1 |
1 |
1 |
|
Output AC |
Rated power |
1KVA |
2KVA |
3KVA |
Rated AC voltage |
120/230V |
120/230V |
120/230V |
|
Rated frequency (Hz) |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
|
Max. output current (A) |
7A |
12A |
13A |
|
THD (rated power) |
<2% |
<2% |
<2% |
|
Power factor at rated power |
≥0.99 |
≥0.99 |
≥0.99 |
|
Connection phases |
Single-phase |
Single-phase |
Single-phase |
|
Efficiency |
Max. efficiency |
97.40% |
97.40% |
97.40% |
European efficiency |
96.70% |
96.70% |
96.70% |
|
Protection |
Input-side disconnection device |
no |
no |
no |
Output-side disconnection device |
no |
no |
no |
|
Grid monitoring |
● |
● |
● |
|
Ground fault monitoring |
● |
● |
● |
|
Insulation monitoring |
● |
● |
● |
|
Electrical isolation |
no |
no |
no |
|
Physical |
Dimensions (W) (mm) |
405*314*135 |
405*314*135 |
405*314*135 |
Package |
3800/40HQ |
3800/40HQ |
3800/40HQ |
|
Weight (Kg)/per unit |
17 |
17 |
17 |
|
Weight (Kg)/per 40HQ |
64600 KGS |
64600 KGS |
64600 KGS |
|
Operating temperature range (℃) |
-25~+60 |
-25~+60 |
-25~+60 |
|
Max self-consumption |
20W/0W |
20W/0W |
20W/0W |
|
Cooling concept |
Self- cooling |
Self- cooling |
Self- cooling |
|
Degree of Protection |
IP65 |
IP65 |
IP65 |
|
Application |
Relative humidity range (non-condensation) |
0~95% |
0~95% |
0~95% |
Max operating altitude above MSL |
2000 m |
2000 m |
2000 m |
|
Feature |
Display |
LCD |
LCD |
LCD |
Communication interface |
RS485 |
RS485 |
RS485 |
|
Certification |
CE |
CE |
CE |
|
Item |
HBF4K |
HBF5K |
HBF6K |
Delivery period (Week) |
1 |
1 |
1 |
|
Type |
Outdoor |
Outdoor |
Outdoor |
|
Input DC |
Max DC power |
4.4KW |
5.5KW |
6.6KW |
Max. DC input voltage |
550v |
600v |
600v |
|
MPP voltage range |
90V-580V |
|||
Rated input voltage (V) |
360V |
360V |
360V |
|
Maximum input current |
20A |
20A |
20A |
|
Number of MPPT inputs |
2 |
2 |
2 |
|
Number of DC inputs |
1 |
1 |
1 |
|
Output AC |
Rated power |
4KVA |
5KVA |
6KVA |
Rated AC voltage |
120/230V |
120/230V |
120/230V |
|
Rated frequency (Hz) |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
|
Max. output current (A) |
20A |
25A |
25A |
|
THD (rated power) |
<2% |
<2% |
<2% |
|
Power factor at rated power |
≥0.99 |
≥0.99 |
≥0.99 |
|
Connection phases |
Single-phase |
Single-phase |
Single-phase |
|
Efficiency |
Max. efficiency |
97.40% |
97.40% |
97.40% |
European efficiency |
96.30% |
96.30% |
96.30% |
|
Protection |
Input-side disconnection device |
no |
no |
no |
Output-side disconnection device |
no |
no |
no |
|
Grid monitoring |
● |
● |
● |
|
Ground fault monitoring |
● |
● |
● |
|
Insulation monitoring |
● |
● |
● |
|
Electrical isolation |
no |
no |
no |
|
Physical |
Dimensions (W) (mm) |
478*344*170 |
478*344*170 |
478*344*170 |
Weight (Kg)/per unit |
16.8 |
16.8 |
16.8 |
|
Operating temperature range (℃) |
-25~+60 |
-25~+60 |
-25~+60 |
|
Max self-consumption |
20W/0W |
20W/0W |
20W/0W |
|
Cooling concept |
Forced cooling |
Forced cooling |
Forced cooling |
|
Degree of Protection |
IP65 |
IP65 |
IP65 |
|
Application |
Relative humidity range (non-condensation) |
0~95% |
0~95% |
0~95% |
Max operating altitude above MSL |
2000 m |
2000 m |
2000 m |
|
Feature |
Display |
LCD |
LCD |
LCD |
Communication interface |
RS485 |
RS485 |
RS485 |
|
Item |
HBF10K |
HBF15K |
HBF20K |
Delivery period (Week) |
1 |
1 |
1 |
|
Type |
Outdoor |
Outdoor |
Outdoor |
|
Input DC |
Max DC power |
10.4KW |
15.6KW |
20.6KW |
Max. DC input voltage |
1000v |
1000v |
1000v |
|
MPP voltage range |
160V-960V |
250V-960V |
250V-960V |
|
Rated input voltage (V) |
600V |
600V |
600V |
|
Maximum input current |
24A |
42A |
42A |
|
Number of MPP inputs |
2 |
2 |
2 |
|
Number of DC inputs |
2 |
2 |
2 |
|
Output AC |
Rated power |
10KVA |
15KVA |
20KVA |
Rated AC voltage |
220/380V |
380V |
380V |
|
Rated frequency (Hz) |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
|
Max. output current (A) |
16.1A |
24.2A |
31A |
|
THD (rated power) |
<2% |
<2% |
<2% |
|
Power factor at rated power |
≥0.99 |
≥0.99 |
≥0.99 |
|
Connection phases |
Three-phase |
Three-phase |
Three-phase |
|
Efficiency |
Max. efficiency |
97.40% |
97.40% |
97.40% |
European efficiency |
96.30% |
96.30% |
96.30% |
|
Protection |
Input-side disconnection device |
no |
no |
no |
Output-side disconnection device |
no |
no |
no |
|
Grid monitoring |
● |
● |
● |
|
Ground fault monitoring |
● |
● |
● |
|
Insulation monitoring |
● |
● |
● |
|
Electrical isolation |
no |
no |
no |
|
Physical |
Dimensions (W) (mm) |
483*452*200 |
709*452*246 |
709*452*246 |
Weight (Kg)/per unit |
22 |
45 |
45 |
|
Operating temperature range (℃) |
-25~+60 |
-25~+60 |
-25~+60 |
|
Max self-consumption |
20W/0W |
20W/0W |
20W/0W |
|
Cooling concept |
Forced cooling |
Forced cooling |
Forced cooling |
|
Degree of Protection |
IP65 |
IP65 |
IP65 |
|
Application |
Relative humidity range (non-condensation) |
0~95% |
0~95% |
0~95% |
Max operating altitude above MSL |
2000 m |
2000 m |
2000 m |
|
Feature |
Display |
LCD |
LCD |
LCD |
Communication interface |
RS485 |
RS485 |
RS485 |
|
Item |
HBF30K |
HBF50K |
HBF100K |
Delivery period (Week) |
1 |
1 |
1 |
|
Type |
Outdoor |
Outdoor |
Indoor |
|
Input DC |
Max DC power |
31KW |
52KW |
110KW |
Max. DC input voltage |
1000v |
1000v |
1000v |
|
MPP voltage range |
250V-960V |
250V-960V |
480V-960V |
|
Rated input voltage (V) |
600V |
600V |
600V |
|
Maximum input current |
42A |
42A |
42A |
|
Number of MPP inputs |
2 |
2 |
2 |
|
Number of DC inputs |
4 |
4 |
4 |
|
Output AC |
Rated power |
30KVA |
50KVA |
100KVA |
Rated AC voltage |
220/380V |
220/380V |
220/380V |
|
Rated frequency (Hz) |
50Hz/60Hz |
50Hz/60Hz |
50Hz/60Hz |
|
Max. output current (A) |
16.1A |
24.2A |
31A |
|
THD (rated power) |
<2% |
<2% |
<2% |
|
Power factor at rated power |
≥0.99 |
≥0.99 |
≥0.99 |
|
Connection phases |
Three-phase |
Three-phase |
Three-phase |
|
Efficiency |
Max. efficiency |
97.40% |
97.40% |
97.40% |
European efficiency |
96.30% |
96.30% |
96.30% |
|
Protection |
Input-side disconnection device |
no |
no |
no |
Output-side disconnection device |
no |
no |
no |
|
Grid monitoring |
● |
● |
● |
|
Ground fault monitoring |
● |
● |
● |
|
Insulation monitoring |
● |
● |
● |
|
Electrical isolation |
no |
no |
no |
|
Physical |
Dimensions (W) (mm) |
767*564*291 |
767*564*291 |
737*713*297 |
Weight (Kg)/per unit |
68 |
70 |
125 |
|
Operating temperature range (℃) |
-25~+60 |
-25~+60 |
-25~+60 |
|
Max self-consumption |
20W/0W |
20W/0W |
20W/0W |
|
Cooling concept |
Forced cooling |
Forced cooling |
Forced cooling |
|
Degree of Protection |
IP65 |
IP65 |
IP65 |
|
Application |
Relative humidity range (non-condensation) |
0~95% |
0~95% |
0~95% |
Max operating altitude above MSL |
2000 m |
2000 m |
2000 m |
|
Feature |
Display |
LCD |
LCD |
LCD |
Communication interface |
RS485 |
RS485 |
RS485 |
|
|